10.5kv 2000kw High Voltage Load Bank for Generator UPS Testing
10.5kv 2000kw High Voltage Load Bank for Generator Ups Testing1.Product IntroductionAC10.5KV 2000KW High Voltage Load Ba
Basic Info
Model NO. | 10.5KV 2000KW AC |
Voltage | AC10.5kv |
Frequency | 50Hz |
Rated Power | 2000W |
Insulation Grade | F Class |
Protection Grade | IP54 |
Transport Package | Container |
Specification | 6058mm*2438mm*2591mm (L* W* H) |
Trademark | Triumph Load |
Origin | Hebei, China |
HS Code | 903033900 |
Production Capacity | 1000 Sets/Year |
Product Description
10.5kv 2000kw High Voltage Load Bank for Generator Ups Testing1.Product IntroductionAC10.5KV 2000KW High Voltage Load Bank For Generator Set TestingHigh voltage load bank,the optional voltage range is 6.6KV~35KV,can be directly used for large high voltage generator,need not to be equipped with conventional step down transformer.We can also provide regular loadbank for high voltage equipment,need to use step-down transformer together.2.AC10.5KV-2000KW High Voltage Load Bank ApplicationLarge generator system testing in ocean engineering, drilling facilities,ship construction etc fieldFactory testing for generator, static voltage characteristic test, speed characteristic test;Marine generator overload protection test,parallel operation test,reverse power and reverse current protection testAssist shipyard in mooring test,sea trial testAssist with the acceptance of the vessel generator testEliminate the carbon deposition of generatorAs the generator loading systemPeriodic running test for standby generatorUPS inspection and maintenanceShip battery charging/discharging system testingThe acceptance of new system and testing of servicing equipment3.AC10.5KV-2000KW High Voltage Load Bank for Generator Set Working EnvironmentAltitute:≤2500mTemperature:-10°C~50°CHumidity:≤95%RHWorking Mode:Continuous work(>6hours continuous long-term work per day)4. AC10.5KV-2000KW High Voltage Load Bank for Generator Set Technical SpecificationsLoad a single set of system parameters | |
Rated voltage and frequency | AC 3 phase 4 wire, 10.5KV/50Hz |
Maximum load power | Resistive Load: 2000KW |
Load Resolution | 100KW,200KW,200KW,500KW,500KW,500KW,6steps |
Power Factor | 1 |
Load accuracy (per file) | ± 5% |
Load accuracy (whole) | ± 3% |
Display accuracy | 0.5 |
Control Power | External AC 3 phase 4 wire, 380V/50Hz |
Wire Connection | Load bank input--Copper bar (star coupling "Y")Control power input--Connector-bar |
Wiring port design | Allow sufficient space to ensure that users can easily access the load cables.External load penetrating openings in the cables after the cables have sufficient waterproof capability, and sufficient mechanical strength. |
Communication Interface | RS485, RS232 |
And machine methods | Computer software and machine |
Insulation class | Class F |
Protection class | IP55 |
Noise | 3 m away from the outlet is less than 9 0 db |
Way of Working | Continuous working |
Cooling | Forced air cooling, horizontal inlet air, vertical exhaust cooling |
Chassis construction | Container package, with up to the top of the ladder, with inlet and outlet grilles and door protection |
Enclosure | Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door |
Transportation | Hoisting, there are lifting lug in top of casing |
Chassis Size | Approximately 5000mm × 2500mm × 2896mm (L × W × H) |
Weight | Approximately 6000kg |
Work environment parameters | |
Workplace | Coastal areas, outdoor work |
Operating Temperature | - 25 ºC ~ + 6 0 ºC (lower limit of the instrument's temperature-10 ºC) |
Relative Humidity | ≤ 95% |
Altitude | ≤ 2500m |
Atmospheric pressure | 86 ~ 106kPa |