Category
100V 150V 200V 300V 400V 500V 600V 800V 900V 1000V High/Large Power High Precision 100kw AC DC Programmable Digital Test Electronic Load for Battery Tester
Product Features: 1.Three phase p.f.c feedback design, DC / DC two-way conversion two-stage circuit, electrical isolatio
Basic Info
Model NO. | ACME800-200DEL |
Voltage Regulating Mode | Width Modulation Type |
Power Supplying System | Terminal Power Distribution Equipment |
Energy Transmission | Two-way Transmission |
Modulation System | PWM |
Certification | CE, ISO |
Brand | Acme |
Power | 0-1000kw |
Input | 380V |
Input Frequency | 47-63Hz |
PF | 0.99 |
Thd | 3% |
DC Voltage | 0-1000V |
DC Current | 0-1000A |
Voltage Ripple | 0.2%Fs |
Current Ripple | 0.3%Fs |
Voltage Stability | 0.2% |
Current Stability | 0.3% |
Load Adjust | 0.1% |
Cc Accuracy | 0.3% |
Constant Resistacne Accuracy | 0.5% |
Time Accuracy | 0.1s |
Transport Package | Wood Packing |
Specification | 200kw |
Trademark | ACME |
Origin | Jinan |
HS Code | 8543709990 |
Production Capacity | 200PCS/Month |
Product Description
Product Features:1.Three phase p.f.c feedback design, DC / DC two-way conversion two-stage circuit, electrical isolation;
2. The load has dual mode operation of power supply and load;
3.Power mode: with constant voltage, constant current, constant power mode output, automatic cross conversion, maintaining the control and protection characteristics;
4.Load mode: with constant voltage, constant current, constant power and constant resistance;
5.Energy feedback, feed network current pollution is small, input power factor is high: > 0.99, and rated working harmonic is less than 3%;
6. Intelligent monitoring function, friendly human-machine interface, can be controlled remotely through CAN bus or PC;
7.It has the function of constant voltage and current, and the voltage and current can be adjusted in full range of 0-rated value, and the power / load can operate in two modes;
8.The whole machine has manual control function and automatic control function;
9.Power access and output interface, with electrical safety protection function;
10.The equipment has the functions of phase loss, overcurrent, overvoltage, overload and short circuit protection;
11.Can be customized according to customer needs
Product application
Charge and discharge test of capacitor and super capacitor
New energy vehicle motor, electric control test, power battery test
DC charger and charging pile test
Energy storage inverter and converter test
Vehicle transmission system and powertrain system test
UPS, EPS system test
Need to replace battery powered test
Product specification:
Model | |
Power | 0-1000kw |
AC characteristics | 3φ4w+pe |
Voltage | 380v±10% |
Frequency | 47Hz - 63Hz |
PF | ≥0.99 (Rating power) |
THD | <3%(Rating power) |
DC characteristics | 0-1000VDC |
Current range | 0-1000A |
Power range | 0-1000kw |
Voltage ripple | 0. 2% fs |
Current ripple | 0.3 % fs |
Voltage stability | ≤±0.2 % fs( fs resistor load ) |
Current stability | ≤±0.3 % fs( fs resistor load ) |
Power adjustment rate | ± ≤0.1 % |
Load adjustment rate | ± ≤0.1 % |
Load characteristics | Constant power accuracy≤±0.5 % fs |
Constant current accuracy | ≤±0.3 % fs |
Constant resistance accuracy | ≤±0.5 % fs |
Time accuracy | setting 0.1 sec+ 0.1 % |
Voltage resolution | 0.1v |
Current resolution | 0.01a |
Setting accuracy | Voltage ±0.2 % fs |
Current | ±0.2 % fs |
Power | ±0.3 % fs |
Measurement accuracy | Voltage ±0.2 % fs±2 dgt |
Current | ±0.2 % fs±2 dgt |
Power | ±0.3 % fs±2 dgt |
Protection | Phase loss, overvoltage, overcurrent, over temperature, overload, short circuit, reverse connection |
Cooling | Forced fan cooling |
Response speed | <10ms |
Display | Touch screen |
Communication interface | rs485/can |
Insulation resistance | Input to shell 20mΩ 500VDC; output to shell 20mΩ 500VDC |
Withstand voltage | Input to shell 1500vac for 1 minute, input to output 1500vac for 1 minute |
Running environment | 0 - 40 ºC (outdoor / - 20 ºC 50 ºC) 20-90% RH |
Remarks | 1. The functions of feedback electronic load, battery charging and discharging, and photovoltaic panel simulation need to be selected by users. 2. The number of channels can be customized according to the user, and the channels can be used in parallel. |